Technical Data for Bluestone

Property Value
Absorption 1.21%
Compressive strength across strata 18,255 lb/in2
Compressive strength with strata 12,388 lb/in2
Flexural strength across strata 2,977 lb/in2
Flexural strength with strata 2,180 lb/in2
Abrasion (Thermal face) 28.2
Abrasion (Natural cleft) 11.2
Specific gravity 2.604
Weight per cubic foot 162.5 lbs